ConSpec

P2635 - Smart Monitor / Controller


Conspec's Smart Monitor/Controller is a State-of-the-Art microprocessor controlled single point monitoring and control processor designed to monitor and display any voltage or current input signal from any sensor source, including Conspec's EZ-CAL Toxic and Combustible Gas Transmitters. The Series P2635 provides State-of-the-Art versatility in monitoring of analog signals. It allows the operator to program the alphanumeric display for standard as well as custom messages and select the ranges of operation as well as set points for activating the relay outputs. A linear analog output signal (0 - 5 VDC or 4 - 20 mA) along with a RS-485 serial port allows for fast and easy integration of the Series P2635 with most SCADA, PLC and Digital Network control systems. The RS-485 and Infrared ports permit closed case data logging, calibration and programming. The P2635 is housed in a weatherproof and explosion proof enclosure at no additional cost.

 FEATURES
  • Single Point Monitoring of Voltages or Current Inputs
  • Compatible with all Conspec Controllers
  • Programmable Alphanumeric Five (5) Digit LED Information Display 
  • Toxic and Combustible Gas Sensors by CONSPEC in PPM, % or LEL
  • Programmable Bar Graph Display
  • Automatic Restart After a Power Interruption
  • Alarm Status and Sensor Fail LED's
  • Stand Alone and Digital Network Ready (DNR)
  • Automatic Calibration Feature with Alarm Blocking
  • Four Programmable Relay Contacts
  • RS-485 Serial Port for Programming Controller & Interrogation by External Computer
  • Long Sensor Life, Quick and Easy Replacement
  • Infrared Port for Closed Case Calibration and Programming with a Laptop Computer 
  • Perfect for Wells and Perimeter Monitoring
  • Password Protected Infrared Programmer
  • CSA / NRTL Approvals
  • 1-Year Warranty 
 TYPES OF GAS MONITORED  INSTRUMENTS MONITORED
Oxygen 0-25% Carbon Monoxide 0-50, 100, 200, 1000 PPM Pressure Transducers in PSI  Vibration in IPS
Chlorine 0-10 PPM Ammonia 0-50 PPM Liquid Level and Flow in Feet or G.P.M. Temperature in C or F degrees
Hydrogen Chloride 0-25, 100, 150 PPM Hydrogen Sulphide 0-25, 50, 100, 200 PPM  Rotating Speed in RPM  Air Flow in FPM
Combustible Gas 0-100% LEL NO, NO2, SO2 and O3 also available Motor Current in AMPS  Load Cells in lbs. or GRAMS of Force
 SPECIFICATIONS
Enclosure Type:  Explosion Proof UL, C.S.A. and FM Approved Enclosure standard for NEC Class I Group B, C, D, Class II Group E, F, G, Class III  Display: Alarm Status and Sensor Fail LED's
Power Input:  9 to 36 VDC  Analog Output Signals: 0 - 5 VDC or 4-20 mA (user selectable)
Operating Temperature: 0 to +40 Degrees C  Analog Input Signals:  Voltage or Current (user selectable)